4.4 Grounding the Pin Pad or Reader
4.4.1 Procedure
1. Orient the mounting plate so that the protruding ears are on top and facing the back of the
reader or PIN Pad. Attach the mounting plate to the junction box using two #6-32 x 3/8” flat
head screws. The mounting plate should be earth ground either to a ground junction box or
directly to an earth ground source (especially if the junction box is not metal).
2. Connect the cable to the rear of the reader at J1. Secure the shield drain lines to one of the
grounding screws in the IQ-400 enclosure.
3. Place mounting holes on the back of the reader over the latches on the mounting plate, and
then position the unit so that the cover is flush with the mounting plate.
4. Secure the unit to the mounting plate by inserting the special security fastener through the
hole in the bottom of the reader. Tighten it using the security driver.
4.4.2 Grounding the Reader Mullion Mount
The reader may be attached to a glass or door mullion separator (either vertically or horizontally)
by using the Mullion Bracket Adapter Kits (04-10170-001 for horizontal mounting, or
04-10171-001 for vertical mounting).
4.4.2.1 Procedure
1. At the IQ-400 end, secure the drain lines to one of the ESD grounding screws in the IQ-400
box. At the reader end, leave the drain line floating. The mullion adapter should be earth
ground either to a grounded junction box or directly to an earth ground source (especially if
the junction box is not metal).
2. Mount the reader to the J-box or mullion bracket.