Sharp IQ-8000 Manual de instalación Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
9.4.5.1 Eight-Reader Expansion Board (P/N: 03-10102-201E) - Jumper Selections
There are five jumper units located on the 8-Reader expansion PCB circuit board. The settings are
shown below.
W1 at Pins 2 and 3 = PCB addressed to the High Address Range
W1 at Pins 1 and 2 = PCB addressed to the Low Address Range
W4 (for Readers e-h)
At pins 1 and 2, 4 and 5, 7 and 8, 10 and 11= Wiegand 5-Wire 5 volt card readers
At pins 2 and 3, 4 and 5, 7 and 8, 10 and 11= Wiegand 5-Wire 12 volt card readers
At pins 2 and 3, 5 and 6, 8 and 9, 11 and 12= PCSC 4-Wire 12 volt card readers
W5 (for Readers i-l)
At pins 1 and 2, 4 and 5, 7 and 8, 10 and 11= Wiegand 5-Wire 5 volt card readers
At pins 2 and 3, 4 and 5, 7 and 8, 11 and 12= Wiegand 5-Wire 12 volt card readers
At pins 2 and 3, 5 and 6, 8 and 9, 11 and 12= PCSC 4-Wire 12 volt card readers
W6 – Reader T/O
At pins 1 and 2 = 32 ms (PCSC Factory Set. Do not
modify)
At pins 2 and 3 = 64 ms
W7-W14 Reader Data Format
At pins 1 and 2 = Wiegand 5-wire (Data 1’s and Data 0’s) format
At pins 2 and 3= PCSC 4-wire (proprietary) format
SW1 Switch Settings (to configure PCB for doors 5-12)
Switch 1 = OFF
Switches 2,3,4,5,6,7,8 = ON = 8 Reader PCB
Switch 5 = ON to enable Supervision Option of ALL Egress Sense Inputs (#24, 26,
28, 30, 32, 34, 36 and 38).
Switch 5 = OFF to disable Supervision of ALL Egress Sense Sense Inputs (#24, 26,
28, 30, 32, 34, 36 and 38).
NOTE Supervised Egress Option requires i4+07.010.02 series (or newer) IQ-400 firmware.
Page xcv of 110 IQ-400 Installation Manual 33-10057-001-C
Vista de pagina 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 124 125

Comentarios a estos manuales

Sin comentarios