9.5 IQ-1200 Features (IQ-400 plus 8-Reader Expansion Module)
2 Auxiliary (Powered) Outputs (cc# 89, 90)
12 Reader Ports:
(Wiegand electrical interface for PCSC and OEM card readers) (readers a-l)
12 Form C Door Strike Outputs (2.0 amps @ 12/24 VDC continuous power)
12 Door Left Open Outputs (or 12 External Shunt Options)
12 Supervised Door Senses (17, 19, 21, 23, 25, 27, 29, 31, 33, 35, 37, 39)
5 Supervised User-Defined (Auxiliary) Sense Inputs (S14, S120, S121, S122, S123)
12 Supervised Request to Exit Inputs (16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38)
Battery Backed Clock Calendar
Flash RAM 128K standard (up to 256K)
Battery-Backed RAM 256K standard (up to 512K)
LEDs for: Power, alarm, on-line diagnostics Reader Data [Error code, door status]
Unsupervised Tamper detect (S13)
9.5.1 System Capacities
Cardholder Capacity: 8,000 (20,000 w/ Memory Expansion)
Time Periods: 32
Holiday Time Periods: 32
Holiday List: 366 Days (Leap Year)
History Transactions: 4,000 regardless of memory size
Enclosure Dimensions: 18”H x 11.5”W x 6”D (45.7cm x 29.2cm x 15.2cm)
Weight: 38 lbs. (17.3kg)
Power: 12VDC
Draw: 3 amp @ 12VDC
Temperature: 32°F to 115°F (0°C to 46°C)
Communications: RS485 standard
RS232 standard
Dial-up standard
Ethernet optional
9.5.2 Electrical Ratings
Power: 12VDC
Draw: 920mA @ 13.65V
Relay Contacts 2 A @ 24 VDC
Data0/Data1 5 Vdc @ 0 mA for Logic 1
0 Vdc @ 5mA for Logic 0
Alarm Point Voltage 5.0 Vdc @ 0.0 mA when Sense Input is in Open Circuit Physical State.
& Tamper Voltage 0.0 Vdc @ 5.0 mA when Sense Input is in Short Circuit Physical State.
1.6 Vdc @ 3.4 mA when Sense Input is in Alarm Physical State.
0.9 Vdc @ 4.1 mA when Sense Input is in Normal Physical State.
Page xcvi of 110 IQ-400 Installation Manual 33-10057-001-C