Vista de pagina 14
The LiNC-NET Network Controller communicates on a multi-point RS485 communication cable
(RS-232, MODEM and LAN communication are also available). You must address each IQ-400
with a unique ID number (1-111) in order to communicate to each IQ-400 panel. Numbering the
IQ-400s should be in ascending order, but it is not required for operation.
NOTE To be installed in accordance with NEC 70. Also should be installed in
accordance with the Standard for Installation and Classification of
Burglar and Holdup Alarm Systems, UL 681.Installation must meet all
local, state, and federal regulations and codes for electrical installation. If
these codes conflict with the installation methods described in this
manual, please call your service representative.
UL LISTINGS The IQ-400 control unit is UL listed to the standard for Access
Control System Units, UL 294. The following card readers have been
found compatible by UL with the IQ-400: PCSC Models BR-370 and
BR-470; HID Models PR-234 and PRK-234; and AWID PR-732, 733.
NOTE: The US Robotics 33.6/56K Sportster modem (Section 7.4) and the
LANtronix MSS1-T RS-232 Serial Terminal Server (Section 8.6) have not
been evaluated by UL, and is not suitable for UL installations.