4. STARTUP
4 - 7
The following explains the test operation select switch, the disabling control axis switch, auxiliary axis
number setting switches, and the axis selection rotary switch.
3ᩴ7ࠣࡔࡦ࠻LED
ᓮゲ⸳ቯ
ࠬࠗ࠶࠴
(SW2)
ゲㆬᛯࡠ࠲ࠬࠗ࠶࠴
(SW1)
ゲ⇟ภഥ⸳ቯ
ࠬࠗ࠶࠴
ᓮゲήല
ࠬࠗ࠶࠴
࠹ࠬ࠻ㆇォಾ឵
߃ࠬࠗ࠶࠴
1
ON
2 3 4
(1) Test operation select switch (SW2-1)
To use the test operation mode, turn "ON (up)" the switch. Turning "ON (up)" the switch enables the test
operation mode. In the test operation mode, the functions such as JOG operation, positioning operation,
and machine analyzer are available with MR Configurator2. Before turning "ON (up)" the test operation
select switch, turn "OFF (down)" the disabling control axis switch.
ᓮゲήലࠬࠗ࠶࠴
"ࠝࡈ(ਅ)"ߦ⸳ቯߒߡߊߛߐޕ
࠹ࠬ࠻ㆇォಾ឵߃ࠬࠗ࠶࠴
"ࠝࡦ()"ߦ⸳ቯߒߡߊߛߐޕ
1
ON
2 3 4
(2) Disabling control axis switch (SW2-2)
Turning "ON (up)" the disabling control axis switch disables the corresponding servo motor. The servo
motor will be disabled-axis status and will not be recognized by the controller.
ᓮゲήലࠬࠗ࠶࠴
1
ON
2 3 4
3-dight, 7-segment LED
Control axis setting switch (SW2)
Rotary axis setting switch
(SW1)
uxiliary axis number setting switch
Control axis deactivation switch
Test operation select switch
Control axis deactivation switch
Set to the "OFF (down)" position.
Test operation select switch
Set to the "ON (up)" position.
Control axis deactivation switch
digit,