3.4.3 Inputting the density of the calibration chip for density detection
Write the calibration target adjustment value (last 2 digits in the barcode, refer to the figure below)
indicated on the shutter label.
The adjustment value of the shutter must be reset when Sheet Color, density sensor, or PU sensor
is replaced.
3.4.3.1 Density Adjustment Menu Setting
For the steps (1) to (8) of menu setting, see Media Thickness Detection Adjustment Calibration
3.4.2.1, steps (1) to (8).
(9) The screen returns to the Adjust Munsell & Media screen. Press Munsell.
(10) Press Yes.
(11) The Munsell sheet correction value input screen appears.