2 SafeCom Controller
D60700-07
2.7.4 Printer web page
The Printer web page can be opened from the Advanced Configuration web
page (2.7.2) by clicking on Printer.
Select Network – Port 9100 if the SafeCom Controller connects to the printer
via the network. On the obsolete SafeCom Controller 3 Port and 1 Port select
Parallel Port if the printer is connected to the SafeCom Controller’s PAR1 port.
Printer IP Address must be correct if the SafeCom Controller is to control
copying on any attached MFP. For fixed IP addresses, use the printer's IP
address. For DCHP IP addresses, use the printer’s hostname.
Use auto-configuration should normally be YES to allow the SafeCom
Controller to automatically determine the Printer Manufacturer and Print
Model. Both of these are used to ensure correct operation of the SafeCom MFP
Cable. SafeCom Go should be YES if Printer Manufacturer is Xerox and the
MFP is EIP-enabled.
Copy Enabled should be YES if a SafeCom MFP Cable is connected to control
copying. The process of enabling Copy Control is MFP dependent and covered in
more detail in 2.6.
Copy Idle Timeout. When the SafeCom controller automatically logs-out the
user after the MFP is idle for a length of time. If Idle timeout is set to 0 there
is no timeout.