AL-1551 USER PROGRAM 11-1
[11]USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
1. Functions which can be set with the user program
*Note:The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
2. Change the setting.
Example: Changing the time to operate the auto shut off function
(Change from 60 sec to 90 sec)
1) Press the right and the left exposure adjustment keys simultaneously
to start setting.
Keep pressing the keys for five sec.
Display lamps ( , , blink simultaneously and " -- " is displayed
on the copy quantity display.
2) Select the function code with the 10-digit key (copy quantity set key).
The number of the selected function blinks on the digit of 10 on the copy
quantity display.
For auto clear, select " 1. "
For setting, refer to the following function codes.
[Cancel] If a wrong code is entered, press the clear key and enter the
correct function code.
* SPF only
3) Press the COPY button.
The number blinking on the digit of 10 of the coyp quantity display is
lighted.
The number of the current set code blinks on the digit of 1.
4) Select the setting code with 1-digit key (copy quantity set key).
To set to 90 sec, select " 3. "
For setting, refer to the following set codes.
* Factory setting
The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
[Cancel] When a wrong number of the function code is set, press the
clear key and perform the procedure again from step 2.
5) Press the COPY button.
The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
Note:To set another function, press the clear key after completion of this
operation and perform the procedure from step 2.
6) Press either one of the exposure adjustment keys ( or ) to
complete the setting.
Display lamps ( , , ) go off and the copy quantity display
returns to the normal state.
Function Contents Factory setting
Auto clear •When a certain time is passed after completion of copying, this function returns to the initial state
automatically. The time to reach the initial state can be set in the range of 30 sec to 120 sec by the unit of
30 sec. This function can be disabled.
60 sec
Pre-heat •When the copier is left unused with the power ON, the power consumption is automatically reduced to
about 40Wh/H (* Note).The time to start this function can be set in the range of 30 sec to 90 sec by the
unit of 30 sec. This function cannot be disabled.
•When this function is operated, the pre-heat lamp on the operation panel lights up.To return to the initial
state, press any key on the operation panel. (When the COPY button is pressed, a copy is made after
returning to the initial state.)
90 sec
Auto shut off passing
time
•When the copier is left unused with the power ON, the power consumption is automatically reduced to
about 18Wh/H (* Note). The time to start this function can be set in the range of 2 min to 120 min.
• When this function is operated, all the lamps except for the pre-heat lamp on the operation panel turn off.
To return to the initial state, press the COPY button.
5 min
Stream feeding Only models with SPF Set
Auto shut off setting •Used to set or cancel this function. Set
Function name Function code
Auto clear 1
Pre-heat 2
Auto shut off passing time 3
Stream feeding 4*
Auto shut off setting 5
Function name Set code
Auto clear 0 (Cancel)
1 (30 sec)
*2 (60 sec)
3 (90 sec)
4 (120 sec)
Pre-heat 0 (30 sec)
1 (60 sec)
2 (90 sec)
Auto shut off 0 (2 min)
*1 (5 min)
2 (15 min)
3 (30 min)
4 (60 min)
5 (120 min)
Stream feeding 0 (Cancel)
*1 (Setting)
Auto shut off setting 0 (Cancel)
*1 (Setting)
Vista de pagina 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 125 126

Comentarios a estos manuales

Sin comentarios

GE JBW3-4 manuels

Manuels d'utilisation et guides de l'utilisateur pour Cuisiniers GE JBW3-4.
Nous fournissons des manuels en pdf 1 GE JBW3-4 à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Cuisiniers GE

Modèles Type de document
MONOGRAM ZEU36KSK/WK/BK Manuel de l'utilisateur   GE MONOGRAM ZEU36KSK/WK/BK User's Manual, 2 pages
JGSP20 Manuel de l'utilisateur   GE JGSP20 User's Manual, 36 pages
JGAS02 Manuel de l'utilisateur   GE JGAS02 User's Manual, 36 pages
ZET1SM Manuel de l'utilisateur   GE ZET1SM User's Manual, 2 pages
EGR3001 Manuel de l'utilisateur   GE EGR3001 User's Manual, 52 pages
JVB37 Manuel de l'utilisateur   GE JVB37 User's Manual, 20 pages
JKP27 Manuel de l'utilisateur   GE JKP27 User's Manual, 28 pages
JCB910 Manuel de l'utilisateur   GE JCB910 User's Manual, 60 pages
JBP22GP Manuel de l'utilisateur   GE JBP22GP User's Manual, 32 pages
PROFILE JT952SK Manuel de l'utilisateur   GE PROFILE JT952SK User's Manual, 2 pages
JGP631ER Manuel de l'utilisateur   GE JGP631ER User's Manual, 16 pages
Profile PGS975DEPBB Manuel de l'utilisateur   GE Profile PGS975DEPBB User's Manual, 2 pages
JGBS80DEMWW Manuel de l'utilisateur   GE JGBS80DEMWW User's Manual, 2 pages
JGKS16 H Manuel de l'utilisateur   GE JGKS16 H User's Manual, 16 pages
JGP622ER Manuel de l'utilisateur   GE JGP622ER User's Manual, 12 pages
JGBS03PK Manuel de l'utilisateur   GE JGBS03PK User's Manual, 24 pages
Profile P2S975DEPBB Manuel de l'utilisateur   GE Profile P2S975DEPBB User's Manual, 2 pages
JDS28CKCC Manuel de l'utilisateur   GE JDS28CKCC User's Manual, 24 pages
JP340WJ Manuel de l'utilisateur   GE JP340WJ User's Manual, 2 pages
ZGU36K Manuel de l'utilisateur    GE ZGU36K User's Manual, 24 pages