11 - 2
11
Target speed
Deceleration
Acceleration
Speed
Startup speed
JOG+
Pulse output
Busy flag
(n+02006)
(n+00002)
n is the top address (in relay units) of the special I/O data area.
[4] Timing chart
The following shows the timing chart during jog operation on the X-axis.
Manual operation
switch or relay
Output pulse
Output pulse
Manual operation
switch or relay
1 pulse is output.
After 1 second, continuous
pulses are output.
Continuous pulses are output.
1 second
interval
1-second wait ON
1-second wait OFF
[5] 1-second wait operation (inching)
When parameter 1 address A+0075 bits 0 to 3 are set to "1" (BCD), the 1st pulse is output, and
continuous pulses are output after a 1-second interval.