FTS 370d/w/r Revision 10 – 1/09/2015 101
Vanguard Controller Board Diagnostics
Register
Address Read/Write Register Name Description / Values
90 R/W
Vanguard Controller
Select
Register
1-6, indicates/selects which system data is reflected below
91 W System wide reboot
Reboots
all controllers for the
entire site. Only applicable
on controller 1 (as set in register 90). Writing any value will
cause the reboot.
92 – 122 R
Vanguard Controller Board
Firmware Revision String
ASCII string, null terminated
123 – 138 R
Vanguard Controller Board
Universally Unique Identifier
Binary data identifier
139 R
Vanguard Controller Board
Input Power Voltage A2D
An A2D value representing the line voltage powering the
controller board and tower
140 R
Vanguard Controller
Internal
Temperature A2D
An A2D value representing the cabinet temperature
141 R
Vanguard Controller
Photodiode
A2D
An A2D value representing the photodiode voltage