FTS 370d/w/r Revision 10 – 1/09/2015 91
Table A-1 – Critical INFORMs
Name
Severity
Description OID
whiteDayAlarmNotify Critical
White Day Alarm (DAY ALARM):
The connected flash head is exhibiting a white
day alarm.
.1.3.6.1.4.1.9882.1.2.1.1.1
whiteNightAlarmNotify Critical
White Night Alarm (WNIGHT ALARM):
The connected flash head is exhibiting a white
night alarm.
.1.3.6.1.4.1.9882.1.2.1.1.2
redNightAlarmNotify Critical
The connected flash head is exhibiting a red
night alarm.
.1.3.6.1.4.1.9882.1.2.1.1.3
beaconCommunicationAlarmNotify Critical
Beacon Communication Alarm (BCN COMM):
The SC 370X is experiencing a communications
failure with the connected flash head.
.1.3.6.1.4.1.9882.1.2.1.1.4
photodiodeAlarmNotify Critical
Photodiode Alarm (PD ALARM):
System 1 Only. More than 19 hours have
passed since the system has changed modes via
the photodiode input.
.1.3.6.1.4.1.9882.1.2.1.1.5
systemPowerFailureAlarmNotify Critical
System Power Failure Alarm (POWER FAIL):
System 1 only. Primary input power failure.
PCB 1 is operating on battery backup to provide
alarm INFORM.
.1.3.6.1.4.1.9882.1.2.1.1.11
towerLightingConfigurationAlarmNotify Critical
Tower Lighting Configuration Alarm (CFG
ALARM):
Indicates that the system is detecting devices
that it is currently not configured to support.
For Example 3 Beacons are detected but the
site is configured for 2.
.1.3.6.1.4.1.9882.1.2.1.1.17
towerLightingSyncAlarmNotify Critical
Tower Lighting Sync Alarm (TWR SYNC):
System 1 only. One or more subordinate units
have not synchronized with System 1 for a
period of one hour or more.
.1.3.6.1.4.1.9882.1.2.1.1.20
plcBindingsAlarmNotify Critical
Bindings Alarm (BIND ALARM):
System 1 only.
The BIND ALARM can be generated by either of
the following conditions:
• One or more controllers are not bound
correctly. A 'SYS COMM' alarm will accompany
the 'BIND ALARM'.
• Two or more controllers are bound to the
same connected equipment (beacon or marker
tier). A 'SYS COMM' alarm will not accompany
the 'BIND ALARM' in this instance. The most
noticeable symptom is a beacon that is not
flashing in 'Sync.' with the rest of the system.
This alarm can be corrected by unbinding then
binding the tower.
.1.3.6.1.4.1.9882.1.2.1.1.21
Comentarios a estos manuales