Sharp SD-AT1000W Especificaciones Pagina 258

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 257
Section-6 Diagnostics
October 17, 2013
62
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
Note
See Figures 6-1, Figure 6-2, & Figure 6-1 for locations of LEDs listed above.
Figure 6-1 PS LEDs - left AC Applied - right AC Applied DC Enabled
Table61PA&PSLEDs
LEDNo.&Name Marking Normal
Faulted
Col
or
Comments
1.Po
werSupplyACOK N/A Green Off GreenwhenACisappliedandwithinrange.
2.Po
werSupplyDCOK N/A Green Off GreenwhenDCoutputisenabledandwithinrange.
3.Po
werSupplyFault N/A Off Red Redwheninternalovertemp.orovercurrentsensed.
4.Po
werAmpUndervoltage UV Off Red RedwhenPAinputvoltage<46V.
5.Po
werAmpOvervoltage OV Off Red RedwhenPAinputvoltage>53V.
6.Po
werAmpTemp.Fault T Off Red RedwhenPAtemp.>85degs.C.
7.Po
werAmpOvercurrent I Off Red RedwhenPAcurrent>14A.
8.PA
BControlFaultSummary Control Green Amber Amberwhencontrolfaultdetected.
9.PA
BFanFaultSummary Fan Green Ambe r Amberwhenfanfaultdetected.
10.PA
BVSWRFaultSummary VSWR Green Amber AmberwhenPAovercurrentfaultdetected.
11.PA
BCurrentFault12.Summary Current Green Amber AmberwhenPAcurrentfaultdetected.
12.PA
BTemp.FaultSummary Temp Green Amber AmberwhenPAovertemperatureisdetected.
13.PA
BPSFaultSummary PS Green Amber AmberwhenPSfaultisdetected.
1 2 3
Vista de pagina 257
1 2 ... 253 254 255 256 257 258 259 260 261 262 263 ... 291 292

Comentarios a estos manuales

Sin comentarios