Section-5 Maintenance
October 17, 2013
548
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
5.9.9 AlternateSoftwareUpdateProcedures
InterruptionsintheISPsoftwareupdateprocessmayresultinanunusableGUIinterface.Thefollowingprocedures
canbeusediftheGUIsoftwareinterfacebecomesinoperable.
5.9.9.1 DirectSoftwareUpdate
TheLPUsoftwarefile(.s19extension)mustbestoredonthePCbeforecommencingtheupdateprocedure.Ifthe
ethernetportonthefrontoftheLPUisstillfunctionalthefollowingprocedurecanbeusedtoloadLPUsoftware:
STEP 1
EstablishanEthernetconnectionbetweenPCandfrontLPUport.
InstructionsformakingthisconnectionareprovidedinSection"2.13.1LPU
AccessviaEt
hernet"onpage221.
STEP 2 OpenawebbrowsersessionusingFirefox(ChromeorIE8alsowork).
STEP 3 Enter192.168.117.88/ISPintotheaddressboxandpressentertodisplaythe
screenshowninFigure532onpage548.
Figure 5-32 Firefox Browser ISP Screen
STEP 4
SelecttheBrowsebuttontonavigatetothedesired.s19softwarefile.
STEP 5 PressSubmitandwatchfortheappearanceandmovementofthe
connectingiconintheupperleftcornerofthebrowserscreen.Theaddress
bardisp laywillchangeto192.168.117.88/Sendfile.Thissteptakesabout23
minutes.
STEP 6 UponcompletionoftheSubmitprocessthe[Program]boxwilldisplay(see
Figure533onpage549).