Section-5 Maintenance
October 17, 2013
524
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
Figure 5-15 Analog Setup Screen 1 Analog Setup Screen 2
Figure 5-16 Analog Setup Screen 3
5.6.2.1 PreliminaryForwardCalProcedure
ThefollowingprocedureisdoneinitiallytoensurethatthetransmitterwillproducethedesiredTPO.TheFinal
AnalogCalProcedureSection5
.6.2.2onpage526mustalsobeperformedtoensurethetransmitterwillmeet
analogs
pecificationsatthe100%synclevel.
STEP 1
Cali bratetheaveragingpowermeterpermanufacturersinstructions.
STEP 2 Connectthepowermetertotheforwardsampleportfromtheprefilter
directionalcoupler.
Note
Ensure that the sample level present at this point (max system output, in dBm, minus the coupling factor)
does not exceed the maximum input range of the power sensor
Note
It is helpful to check the RF DAC value displayed (in Hex) on the calibration screen. In a system which is
properly configured and operating correctly, the low point power level should be obtained at a DAC value
of < 0x300. If you reach a DAC value 0x300 and are not close to the desired target for this step, please
verify that the system is configured correctly, especially if this is a first time turn-on or other service work
has been performed.
STEP 3 Enterthecoupleroffsetvalue(dB)intopowermetertoallowdirectaverage
powerreadings.NOTE:Thepowermeterreadsaveragepower.Conversion
topeakvisualpowerisrequired.
STEP 4 SetthepowermetertoreadinWatts.