Error
chart
for disk system
Error code
[Error message]
Contents
Check item and corrective action
50
1)
Drive fails
to
be ready.
[NO
READY] o Diskette
is
wrongly inserted.
o Fit diskette in correctly.
o Motor does not normally run.
o Check belt and/or drive motor assembly.
o Index detection circuit
is
improper.
o Check index lamp, drive
PWB,
index sensor.
o Flat cable
is
improperly fit
in
or
broken.
o Check flat cable.
o
No
select signal comes
at
drive.
o Check floppy disk I/O card.
o Drive unit door (front door)
is
not
o Close front door.
closed.
o Diskette
is
faulty. o Replace diskette.
o Write operation
is
attempted
in
write
protect state.
54
1)
Drive
[UNFORMAT]
o Head position
is
not
aligned. 0
Replace drive unit.
(off-track state)
o Head and amp. circuit are defective.
0
Replace drive unit and/or drive
PWB
unit.
2) Diskette
o Diskette not formatted
is
in
use.
o Initialize again, or replace diskette
o
CRC
error
in
ID
field.
o
ID
field
is
broken down.
41
1)
Drive
[DISK DATA
o SEEK error
o Check drive unit and diskette
ERROR]
Replace,
if
required.
o Head shift
is
improper.
o Replace drive unit.
2) Diskette
o CRC error
in
data field.
o Data field
is
broken down.
iO
Initialize again,
or
replace diskette.
o
ID
field
is
defective.
o Data mark detection error.
-12-