CHAPTER 9. INSTALLATION OF
SERVICE OPTIONS
1.Paper near end sensor: DUNT-5800BHZZ
[PARTS LISTl
INo. I Parts name I
Parts code
IQ’WIpricel Note 1
I
1 Paper near
DUNT-58 00 BHZZ 1 Az
end sensor unit I
[DISASSEMBLY METHOD]
1)
2)
3)
4)
5)
Remove the PR COVER UNIT.
Remove the TOP CABINET.
Remove the CONTROL PWB.
Solder the accessory connector to the CONTROL PWB.
\
/
Attach the CONTROL PWB.
6)
7)
8)
9)
10)
ER-OIPU
Remove the PRINTER UNIT.
Install the NEAR END SENSOR UNIT @ to the TOP CABINET
@.
X Adjust the height of the NEAR END SENSOR UNIT, and fix it
with the fixing screw.
Install the PRINTER UNIT.
Attach the earth wire from the NEAR END SENSOR UNIT @ to
the BO~OM PLATE ~,
Attach the connector cable from the NEAR END SENSOR UNIT
@to the connector of the CONTROL PWB.
Note: When attaching the near end sensor either to the receipt side
or to the journal side, the connector must be connected to
NESC1 on the control PWB and J6 must be shorted by the
jumper wire.
When both of the receipt side and the journal side are used,
either connector NESC1 or NESC2 can be used and there is
no difference in operations.
I
CONTROL PWB
9-1