maIntenance Intervals
COMPONENT/
SYSTEM
MAINTENANCE
PROCEDURE
REQ'D
SKILL
LEVEL
DAILY OR
BEFORE
USE
EVERY
REFUEL
3 MONTHS
OR 90
HOURS
YEARLY
600 HOURS
Air Filter Inspect/Clean
1 I / C * R *
Choke Shutter Inspect/Clean
1 I / C
Fuel Filter Inspect/Replace
1 I * I / R *
Fuel Cap Gasket Inspect/Replace 1
I * R *
Fuel System Inspect/Replace
1 I (3) * I (3) *
Spark Plug Inspect/Clean
1 I / C / R *
Cooling System Inspect/Clean
2 I / C
Muffler Spark Arrestor Inspect/Clean/Replace
2 I / C / R *
Cylinder Exhaust Port Inspect/Clean/Decarbon
2 I / C
Drive Shaft (Flex Cable
Models)
Grease
2 I (1)
Gear Housing Grease
2 I (2)
Recoil Starter Rope Inspect/Clean
1 I / C *
Screws/Nuts/Bolts Inspect/Tighten/Replace
1 I *
(2) Apply POWER BLENDX
TM
grease every 50 hours of use.
(3) Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.
* Replacement is recommended based on the finding of damage or wear during inspection.
MAINTENANCE PROCEDURE LETTER CODES:
I = INSPECT, R = REPLACE, C = CLEAN
IMPORTANT NOTE
- Time intervals shown are maximum. Actual use and your experience will determine the
frequency of required maintenance.
MAINTENANCE PROCEDURE NOTES:
(1) Apply POWER BLENDX
TM
grease every 25 hours of use.