Note: Do not attempt to remove the orifice body
from the brass adapter since the orifice is
pressed on at the factory to assure a
good seal.
4. Install orifice assembly, insure orifice assembly
is wrench tight in burner.
5. Reconnect flare nut to orifice assembly.
6. Leak test all gas fittings removed.
Burner Removal & Replacement
USE TWO WRENCHES WHEN TIGHTENING OR
UNTIGHTENING GAS FITTINGS. LEAK TEST AF-
TER WORKING ON ALL GAS FITTINGS. FAILURE
TO DO SO COULD RESULT IN A GAS LEAK
WHICH COULD RESULT IN A FIRE OR EXPLO-
SION, WHICH COULD CAUSE PERSONAL IN-
JURY OR DEATH.
1. Turn off the gas supply at the main tank.
2. Remove the flare nut from the burner orifice as-
sembly.
3. Remove the burner box cover.
4. Remove the screw that secures the burner to
the burner bracket, and pull the burner from the
bracket.
5. Remove the orifice assembly from the burner.
6. To reinstall reverse the procedure.
7. Leak test gas fittings removed.
Refrigerator Removal & Reinstallation
1. Remove the AC cord from the AC receptacle.
2. Turn off the gas supply at the main tank.
3. Remove the LP gas supply line from inlet fitting.
4. Remove the two screws from the back of the re-
frigerator that secure the refrigerator to the floor.
5. Remove the four screws from the breaker that
secure the refrigerator into the cut-out opening.
6. Slide the refrigerator forward and lift out of the
opening.
7. To reinstall, insure that the seal strips around
the breakers are in place and reinstall by revers-
ing Steps 6 through 1.
CARE MUST BE EXERCISED UPON REMOVAL
AND RE-INSTALLATION OF THE REFRIGERA-
TOR TO INSURE THAT THE SEAL STRIPS LO-
CATED BEHIND THE MOUNTING FLANGES ARE
NOT DAMAGED, MISPLACED OR MISALIGNED.
THESE SEALS SERVE AS A COMBUSTION SEAL
WHICH PREVENTS EXHAUST FUMES FROM EN-
TERING INTO THE LIVING QUARTERS.
8. Leak test all gas fittings removed.
WARNING
WARNING
21