Vista de pagina 37
7·9
7
[2] JW-2PU
· Open the terminal block cover, fasten with the screw with torque of less than 12kg·cm.
· Halt output lines can not be connected serial. To use more than two sets, use a relay for
interconnec-tion.
Connect the DC relay in the halt output line and insert the contact with the emergency stop
circuit.
24 VDC
INPUT
GND
1
8
2
3
4
5
6
7
+
-
Terminal block
cover
Terminal block
cover
Do not use.
In case of 24 VDC input
The coil rating must conform to the power supply voltage.
DC relay
Halt output
line
留意点
Remarks
· Connect without confusing polarities of input power supply and halt output signal.
· Wrong polarity connection may damage the power supply module when charged.
Halt output internal circuit