Sharp AF-P80CX Manual de servicio Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
2
AF-P80CX
SPECIFICATIONS
Models AF-P80CX
Cooling capacity BTU/h 8000
Moisture removal Pints/h 2.3
ELECTRICAL DATA
Phase Single
Rared frequency Hz 60
Rated voltage Volts 115
Rated current Amps 6.7
Rated input Watts 730
Power factor % 95
EER BTU/Wh 11.0
COMPRESSOR
Type (Hermetically sealed rotary type)
Model, Motor output 2R12T126A-6A, 550W
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, Hair pin
Condenser Louver fin, Grooved tube, 7mm, Hair pin
Control O.D. x I.D. x Length x Q'ty(mm) 2.7 x 1.0 x 800 x 2
(Capillary tube)
Refrigerant volume R-22(OZ) 15.5
(Factory change)
NET DIMENSIONS
Width Height Depth
inches(mm)
19-11/16(500) x 14-9/16(370) x 17-3/32(434)
Net Weight lbs 53
GROSS DIMENSIONS
Width Height Depth
inches(mm)
22-27/32(580) x 18-5/16(465) x 19-31/32(507)
Gross Weight lbs 60
FAN SYSTEM
Indoor side(Evaporator) Centrifugal fan
Outdoor side(Condenser) Propeller fan
Air flow rate(indoor side) CFM High / Med / Low
187 / 173 / 155
OTHERS
Safety devices Compressor: Overload relay
Fan motor: Internal thermal protector
Air filter Polypropylene net
Power cord length ft 6.0
Power plug type 125V, 10A