AE-XM30GR
5 – 2
7. Cut the insulators.
8. Remove the 2 screws fixing the control box cover.
CAUTION: Discharge electrolytic capacitor before touching this capac-
itor or other components or wirings.
9. Cut the wire fixing bands (3 points). Disconnect the 7 connectors.
Fan motor / Reverse valve Thermistor/ Expansion valve
10.Disconnect the 2 terminals.
11.Remove the compressor cover.
12.Remove the terminal cover and disconnect 3 terminals.
NOTE: Caution to the connectors' position when reinstalling.
13.Remove the 5 screws fixing the control box assembly.
14.Cut the 2 insulator.
Screws
Cut
Cut (3 points)
Compressor cover
White (C)
Red (S)
Orange (R)
Thermistor (Red)
Compressor
Cut