M. Operating voltage/power consumption
Sub-
sidiaries
Power
supply
voltage/
frequency
Power consumption
Power
save
mode
Ready
mode
Power
shut-
down
mode
Average
(during
printing)
Max.
120V
50/60Hz
29 Wh/h 55 Wh/h 17 Wh/h 171 Wh/h 600 W
220–240V
50/60Hz
35 Wh/h 64 Wh/h 18 Wh/h 175 Wh/h 600 W
(Within Rated voltage ± 10% and Rated frequency ± 2%)
N. Safety/environmental standard
(1) Safety/environmental standard
Item Standard name Country
Safety standard SEMKO Sweden
NEMKO Norway
DEKRA (GS MARK) Germany
BSI U.K
CUL UL USA/Canada
FDA USA
Radio wave noise
standard
CE MARK Europe
C-TICK Australia
FCC USA/CANADA
Energy standard ENERGY STAR World wide
(Printer only)
Environmental
standard
——
(2) Ozon level
Very low (unmeasurable level)
(3) Noise level
Noise mode
Individual
Operating
mode
Ready mode
Power
shut-down
mode
Sound power
level
66 40 0 dB
Sound
pressure level
54.8 dB 0 dB
O. Ambient conditions
(1) Occupied area
Main unit 460 × 650 mm (18.2 × 29.53 in.)
(2) Operating conditions
(3) Storage conditions (packed in the packing material)
(4) Transport condition (packed in the packing material)
(5) Atmospheric pressure
595 mmHg or above
(6) Standard condition
20 to 25°C 65±5% RH, Rating for different countries
10˚C 35˚C
85%
20%
30˚C, 85%
35˚C, 60%
Humidity
Temperature
RH
–10˚C 50˚C
90%
10%
40˚C, 90%
50˚C, 60%
Humidity
Temperature
RH
Machine
–10˚C 40˚C
90%
10%
40˚C, 90%
Humidity
Temperature
RH
Supply
25˚C 40˚C
90%
15%
30˚C, 90%
40˚C, 60%
Humidity
Temperature
RH
Machine
10˚C 40˚C
90%
10%
40˚C, 90%
Humidity
Temperature
RH
Supply
FO-3800M