28
Input range: [36] to [60] (1 = 0.5 mm)
Default: [48]
Diagram showing the accordion fold position
3.5.4 Double Fold Position Adjustment
This performs adjustment of fold position for double fold.
1) Select [Double Fold Position Adjustment] in the Folding
Unit screen.
2) Adjust the double fold position for when the folding unit
is installed.
The 10-key pad appears when each of the textboxes is
tapped. Enter the desired values.
Input range:
A4R/Letter R (8 1/2 x 11R): [46] to [60] (1 = 0.5 mm)
Default: [48]
A4R/Letter R (8 1/2 x 11R): [50] to [60] (1 = 0.5 mm)
Default: [52]
Diagram showing the double fold position
3.5.5 Z-Fold Position Adjustment
This performs adjustment of fold position for Z-fold.
1) Select [Z-Fold Position Adjustment] in the Folding Unit
screen.
2) Adjust the Z-fold position for when the folding unit is
installed.
The 10-key pad appears when each of the textboxes is
tapped. Enter the desired values.
Input range: [46]-[53]
The default is [50].
Diagram showing the Z-fold position
Default: -1 mm
Increment: 0.5 mm
Default: 1 mm
Increment: 0.5 mm