Sharp AR-810 Manual de usuario Pagina 74

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 101
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 73
AR-651/810 TROUBLE SHOOTING 5 - 74
[C85] Lifting tray motor error
Is the lifting tray lifted when originals are set on the feeding tray?
Is the loading of the lifting tray normal?
Adjust the mechanical loading. Remove, if any, extraneous
materials.
Is the power voltage for CN5-5 and CN6 on the ADF board 24V?
1. Replace the ADF board.
2. Perform the EEPROM initialization of RADF, sensor
automatical adjustment and tray width sensor adjustment.
Replace the lifting tray motor.
Is the upper limit sensor working properly when the lifting tray is lifted?
Replace the upper limit sensor.
Is the lifting tray lowered when originals are removed from the original tray?
Is the loading of the lifting tray normal?
Adjust the mechanical loading. Remove, if any, extraneous
materials.
1. Replace the lower limit sensor.
2. Replace the ADF board.
3. Perform the EEPROM initialization of RADF, sensor automatical adjustment and tray width
sensor adjustment.
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
NO
YES
Vista de pagina 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 100 101

Comentarios a estos manuales

Sin comentarios