showlogs(8)
System Administration 313
Case where the -v option is specified
Temperature and humidity record
Date Message
Mar 30 17:45:31 JST 2005 System power on
Switch= Service RCIaddr=000105ff
Code=xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Date: Log collection date and time (month day hour:minute:second
time-zone year)
The displayed time is the local time.
Message: Event message
Switch: Status of the mode switch of the operator panel
One of the following states are displayed:
Locked Normal operation mode
Service Service mode
RCIaddr: Remote Cabinet Interface (RCI) address
If RCI is supported, the RCI address is displayed as an eight-
digit hexadecimal number.
Code: Detailed event information
The displayed information is in hexadecimal format
Date Temperature Humidity Power
Mar 30 17:45:31 JST 2005 32.56(C) 60.20% Main Line Switch OFF
Mar 30 17:55:31 JST 2005 32.56(C) 60.25% Main Line Switch ON
:
: