On-line Configuration Programming
Use the following procedure to select the on-line configuration programming.
Please consult your dealer for more details.
1.
In the SETTING window, select “20 ONLINE CONFIG”.
• The ONLINE CONFIG window will appear.
2.
Program each item as follows:
TERMINAL No. (Use the numeric entry)
Terminal number (0 to 999999).
CI SIGNAL (Use the selective entry)
Sensing of the CI signal
NON
SENSING
LINE FORM (Use the selective entry)
Programming of the modem control
FULL: Full duplex system
HALF: Half duplex system
BAUD RATE (Use the selective entry)
Transmission data rate
38400 bps 19200 bps 9600 bps
4800 bps 2400 bps 1200 bps
600 bps 300 bps
START CODE (Use the numeric entry)
Start code (0 to 127)
END CODE (Use the numeric entry)
End code (0 to 127)
TIME OUT (Use the numeric entry)
Programming of the time-out time (1 to 255 sec.)
Procedure