STP-200/300/400 Series Instruction Manual
15.2 Abnormalities When Powering ON
(When any "Abnormality/Error Warning" lamp lights, see Section 15.5, "When
any Abnormality/Error Warning Lamp Lights.")
Table 15.1 Troubleshooting after Powering ON
No. Symptom Probable Cause Countermeasures
Referred
Section
Incorrect connection of
the power cable.
Connect the power cable
correctly.
4.4.2
Blown fuses F2, F4. Replace blown fuses. 4.1.3
12.3
A
bnormal power
voltage
Set the voltage to the
rated voltage ±10%.
4.4.2
16.2
Power failure. Check whether or not a
power failure has
occurred.
6.1.1
1
The "POWER ON/OFF"
switch built-in lamp
(green LED) does not
light, when powering
ON.
Remote signal input
error
(REMOTE operation
only)
Check the remote signal
for voltage, polarity, and
pin number.
5.6.1
8.1
15.3 Abnormalities When Performing the STP Pump Start Operation
(When any "Abnormality/Error Warning" lamp lights, see Section 15.5, "When
any Abnormality/Error Warning Lamp Lights.")
Table 15.2 Troubleshooting When Performing the STP Pump Start Operation
No. Symptom Probable Cause Countermeasures
Referred
Section
The
"MANUAL/REMOTE"
changeover switch is not
in the correct position.
Slide the
"MANUAL/REMOTE"
changeover switch on the
rear panel of the STP
control unit to the
correct position.
4.1.2
5.5
5.6
1 The "ACCELERATION"
lamp does not light.
Remote signal input
error (during REMOTE
operation only)
Check the remote signal
for voltage, polarity, and
pin number.
5.6.1
8.1
15-2