Part # 471950 Revision #E
© HydroTemp Manufacturing Co., Inc.
Note: Specifications may change without notice.
AIR SOURCE UNIT
INSTALLATION MANUAL
POOL/SPA HEATERS, CHILLERS,
REVERSE CYCLE & COMMERCIAL MODELS
FOR QUALIFIED TECHNICIANS ONLY
Models:
MiniMax Plus HP 400 (XLS400)
MiniMax Plus HP 600 (XLS600)
MiniMax Plus HP 800 (XLS800)
MiniMax Plus HP 1000 (XLS1000)
MiniMax Plus HP 230 (CP12)
WARNING
FOR YOUR SAFETY - READ BEFORE OPERATING
Warning: If you do not follow these instructions exactly, a fire or explosion may result, causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, alteration, service or maintenance may cause property damage, personal injury or
death. Installation and service must be performed by a qualified technician or service agency.
!
!
Vista de pagina 0
1 2 3 4 5 6 ... 43 44

Indice de contenidos

Pagina 1 - INSTALLATION MANUAL

Part # 471950 Revision #E © HydroTemp Manufacturing Co., Inc.Note: Specifications may change without notice.AIR SOURCE UNITINSTALLATION MANUALPOOL/SPA

Pagina 2 - 239-768-1555

CHEMICAL PROTECTION PRECAUTIONS10NO CHEMICALSIN SKIMMER !!!IN LINE TYPECHLORINATOROFF LINE TYPECHLORINATORTOPOOL2 LBCHEMICALRESISTANTCHECK VALVE(PN#

Pagina 3

CAUTIONPROTECT HEAT EXCHANGERYou want to prevent any chemicals from runningthrough the piping and heat exchanger of the heater.Eliminate chlorinating

Pagina 4 - SPECIAL FEATURES

TWO UNIT INSTALLATIONSTANDARD PLUMBING 1 OR 2 UNITSUp to 90 GallonsPer MinuteMaximum FlowPer Unit BeforeOptional ExteriorBypass IsRequired."Verti

Pagina 5

:::::POOL & SPA COMBO PLUMBINGManual3-WayValveMotorDriven3-WayValveHeating a connected pool and spa spill over with one heater. For a single pump

Pagina 6 - Bulkhead

SEPARATE POOL & SPA PLUMBINGHeating a separate pool & spa, "without" a spill over, with one heater. Two pump system.The following sc

Pagina 7 - CAUTION

SPECIAL NOTE: Do not run water through the solar panels at night or on very cloudy days. This will have acooling effect and counteract the heat pump

Pagina 8 - PLUMBING & WATER FLOW

16COMMERCIAL PLUMBINGWhen plumbing a heating system into a high rate commercial filtering system, you should be prepared to evaluatethe entire system

Pagina 9 - HIGH RATE WATER PUMPS

17Check Valve & LoopAll chemical injection devices must be"down line" of the check valve & loop.(If applicable)In Line TypeChlorinat

Pagina 10

SOLAR PANELSIf you have a solar system plumbed in the same systemas the heat pump, you may experience static pressureon certain brands of solar panels

Pagina 11 - PROTECT HEAT EXCHANGER

WATER FLOW SWITCH INSTALLATIONPlumb the optional water FLOW switch externally on the water"in" piping. Position the flow switch on the wa

Pagina 12 - HP OR 90 GPM

WARNINGFOR PROFESSIONAL USE ONLYTrained Technicians Only !2Owners/users/installers should contact the factory service department for advice at239-768-

Pagina 13 - POOL & SPA COMBO PLUMBING

THERMOSTATSPAMODEMODEREADYPOOLCONTROLWATER SWT-STATLOW PRESS.HIGH PRES.OKOKOKOKPRE-START UP PROCEDURES20CHECK FLOW AT AUTO BYPASSMake sure the pump is

Pagina 14

21WATER HEAT EXCHANGERThe compressed hot gas releases its heat to thepool water inside the heat exchanger. The ex-changer is a tube within a tube cons

Pagina 15 - Or Optional

22Turn the adjustmentclockwise and theswitch will require"more" pressure riseor drop to activateand deactivate theheater.Turn the adjustment

Pagina 16 - COMMERCIAL PLUMBING

23 SHUT DOWN & FREEZE PROTECTION PROCEDURESWhen shutting the unit down for the end of the swimming season, you must consider some items to prot

Pagina 17

REQUIRED BONDING TO POOL STEELMake sure that the unit cabinet is bonded to the poolsteel. Most codes require that the circulation pump bebonded as we

Pagina 18 - SUCTION LEAKS

HP800A-1E40º-105ºBTUH/COP82,000/3.5127,000/4.7Auto/InternalExt. Field Install15-902.2@30GPM60º-105ºF2"PVC208 or 2301 Phase#6601/31.94,2501,07522&

Pagina 19

26HP1000R-1EBTUH/COP71,000/3.0124,000/4.6BTUH/EER94,000/12.4Unit MountedAuto/InternalExt.Field Install15-903.1@50GPM60º-105ºF2"PVC208 or 230*1 P

Pagina 20 - PRE-START UP PROCEDURES

THERMOSTATSPAMODEMODEREADYPOOLCONTROLWATER SWT-STATLOW PRESS.HIGH PRES.OKOKOKOKExternal Access Panel( 7, Phillips Head Screws)To run the main 240 vol

Pagina 21 - OPERATIONAL SEQUENCE

Ground Lugto Main Supplyfor Ground WireCompressorCapacitorFan RelayFactory WiringLoad Side(Bottom)To CompressorDO NOT CHANGE !Fan Capacitor24 VoltTran

Pagina 22 - WATER PRESSURE SWITCH CHECK

WIRING DIAGRAM SCHEMATIC FOR DUAL THERMOSTAT UNITS 208-230 VOLT/SINGLE PHASEMODELS: S300, S500, S700, S900, P4000, P5000, P6000, P7000, XL350, XL550,

Pagina 23

3INSTALLATION MANUAL - TABLE OF CONTENTS1. HEAT PUMP DESIGN FEATURES ...

Pagina 24 - EQUIPMENT COMMON BONDING

30WIRING DIAGRAM SCHEMATIC FOR DUAL THERMOSTAT UNITS 208-230 VOLT/THREE PHASEModels: XLS1000, HP1000 & CP12.

Pagina 25 - Pool/Spa Heat Pumps

31WIRING DIAGRAM SCHEMATIC FOR SINGLE THERMOSTAT UNITS 208-230 VOLT/SINGLE PHASEREVERSE CYCLEModels: XLS800R, HP800R, XLS1000R, HP1000R & XLS1000R

Pagina 26 - PERSONAL

32WIRING DIAGRAM SCHEMATIC FOR SINGLE THERMOSTAT UNITS 208-230 VOLT/THREE PHASEREVERSE CYCLEModels: XLS800R. XLS1000R, HP800R & HP1000R & CP12

Pagina 27 - 2, 5/16" Hex Head Screws

33LowVoltageHeaterconnectionsat CompoolcontrollerHow to hook up a heat pump to a Digital Compoolfor Models CP3800, CP3600, CP340002 wire connections1)

Pagina 28 - HIGH VOLTAGE COMPARTMENT

34How to hook up a heat pump to a Non Digital Compoolfor Models CP100 & CP303 wire connections12345678TB2DUAL POT BEZELPoolPot.DialSpaPot.DialL.E.

Pagina 29

35Risk of electrical shock or electrocution.Improperly installation will create an electrical hazard which could result in death or serious injury to

Pagina 30

36Control Ready light ON.Water Press. OK light ONT-Stat On light ONFan is not turning.Unit will not start. Low water flow through heater. Dirty or

Pagina 31 - REVERSE CYCLE

37WARRANTY & DEALER SERVICEWhen requesting factory warranty service, please follow these guidelines to insure a smooth process.PROBLEM DESCRIPTION

Pagina 32

38GLOSSARY OF TERMSA/C Contractor: A company licensed by the state and local au-thorities to perform heating ventilation and air-conditioning in-stall

Pagina 33 - 2 wire connections

Circuit Breaker: An automatic switch that will shut the power offto an electrical device (heater, circulation pump) when an over-load or short occurs

Pagina 34 - 3 wire connections

4Super Quiet & Highly Efficient Compressor DesignSturdy ElevatedFiberglassRust ProofBottom ProvidesProper DrainageLarge Aluminum & CopperLanc

Pagina 35 - OWNER TROUBLE SHOOTING GUIDE

40Floating Chlorinator: A device that floats on the pool waters sur-face that feeds chlorine to the water by eroding solid tablet typechlorine, insid

Pagina 36

Run Dry: When any pool equipment is running without water,usually causing some sort of damage.Serial Number: A twelve digit number on the identificat

Pagina 38 - GLOSSARY OF TERMS

This page is blank.43

Pagina 39

Manufactured by:© 2002 HydroTemp Manufacturing Co., Inc.239-768-1555www.warmpool.com Heat Pumps

Pagina 40

THERMOSTATSPAMODEMODEREADYPOOLCONTROLWATER SWT-STATLOW PRESS.HIGH PRES.OKOKOKOK5 The electrical panel has anisolated compartment, locatedwithin

Pagina 41

CLEARANCE & AIR FLOWPrepare a level area near the pool/spa filtering system.Remove any plants or equipment that do not meet theminimum clearance r

Pagina 42 - This page is blank

SPRINKLER LOCATIONRelocate or remove any sprinkler heads that have thechance of spraying on or into the unit. Make sure thereare absolutely no sprinkl

Pagina 43

70 GPM "Cold"In20GPMtoCoil"Cold"50 GPMBypassedOut10˚-15˚TempRise"Hot"Hot & ColdMix HereTHERMOSTATSPAMODEMODEREADYPOO

Pagina 44 - Heat Pumps

Position the valve so that the access panel can beeasily removed, always check before final glu-ing. Angle the valve out 45˚ to provide adequatecleara

Comentarios a estos manuales