Sharp XG-C68X Ficha de datos Pagina 90

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 106
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 89
Lamp
unit
AN-C55LP
User service screw
Removing and Install-
ing the Lamp Unit
Info
• Make sure that you remove the lamp by
the handle. Do not touch the glass sur-
face of the lamp unit or the inside of the
projector.
• To avoid injury to yourself and damage
to the lamp, ensure to carefully follow the
steps below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
(Only the silver screws are loosened).
1 Press
STANDBY
on the projector
or
on the remote control to
put the projector into the
standby mode.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2 Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3 Change the air filter.
• Change the air filter whenever you in-
stall the lamp unit (see pages 81 and
82).
4 Remove the lamp unit cover.
• Loosen the user service screw that
secures the lamp unit cover. Then
open the cover in the direction of the
arrow.
-86